R-134a汽車空調系統使用 R-152a替代冷媒之研究
dc.contributor | 李景峰 | zh_TW |
dc.contributor | 謝建新 | zh_TW |
dc.contributor | Li, Jeen-Fong | en_US |
dc.contributor | Sie, Jian-sin | en_US |
dc.contributor.author | 李俊毅 | zh_TW |
dc.contributor.author | Li, Jyun-Yi | en_US |
dc.date.accessioned | 2019-09-04T01:50:37Z | |
dc.date.available | 2021-09-28 | |
dc.date.available | 2019-09-04T01:50:37Z | |
dc.date.issued | 2019 | |
dc.description.abstract | 本研究旨利用R-152a冷媒替代R-134a作為汽車用冷氣機之替代品,藉以提昇其性能。性能測試於室內條件(乾球溫度為27±1°C,濕球溫度19±0.5°C),不同冷凝條件溫度(35±1°C、36±1°C、37±1°C、38±1°C、39±1°C及40±1°C)及不同壓縮機轉速(1000rpm、1400rpm、1800rpm、2200rom、2600rpm、3000rpm)進行性能測試。結果顯示,R-152a冷媒替代R-134a作為汽車用冷氣機,在冷凝器入口端高壓壓力降低9.72%-16.12%,壓縮機排氣溫度方面升高了2.214%-11.954%,性能係數(COP)提升了2.829%-37.495%, 能源效率比(EER)值提升了1.299%-34.678%,可用能效率值(ɛ)提升了7.258%-25.806%,可用能係數(EPC)提升了4.717%-22.727%。 | zh_TW |
dc.description.abstract | This study aims to replace R-134a with R-152a as an alternative refrigerant to the mobile air conditioning system, and improve it’s performance. The performance testing was fixed the same indoor conditions (dry bulb temperature is 27±1°C wet bulb temperature is 19±0.5°C), six different condenser temperature (35±1°C 36±1°C, 37±1°C, 38±1°C, 39±1°C, 40±1°C) and six different compressor speeds. According to the result, it showed that using R-152a as a refrigerant has better effect in R-134a. In the performance testing, the condenser pressure reduced 9.72%-16.12%, the discharge temperature increased 2.214%-11.954%, COP improved 2.829%-37.495%, EER improved 1.299%-34.678%, exergy efficiency (ɛ) improved 7.258%-25.806%,exergetic performance coefficient (EPC) improved 4.717%-22.727% in the R-152a mobile air conditioning system. | en_US |
dc.description.sponsorship | 工業教育學系 | zh_TW |
dc.identifier | G060670020H | |
dc.identifier.uri | http://etds.lib.ntnu.edu.tw/cgi-bin/gs32/gsweb.cgi?o=dstdcdr&s=id=%22G060670020H%22.&%22.id.& | |
dc.identifier.uri | http://rportal.lib.ntnu.edu.tw:80/handle/20.500.12235/98662 | |
dc.language | 中文 | |
dc.subject | R-152 | zh_TW |
dc.subject | R-134a | zh_TW |
dc.subject | 壓縮排氣溫度 | zh_TW |
dc.subject | 性能係數(COP) | zh_TW |
dc.subject | 能源效率比(EER) | zh_TW |
dc.subject | 可用能效率 | zh_TW |
dc.subject | 可用能係數 | zh_TW |
dc.subject | R-152 | en_US |
dc.subject | R-134a | en_US |
dc.subject | Discharge temperature | en_US |
dc.subject | Coefficient of Performance (COP) | en_US |
dc.subject | Energy efficiency ratio (EER) | en_US |
dc.subject | exergy efficiency (ɛ) | en_US |
dc.subject | exergetic performance coefficient (EPC) | en_US |
dc.title | R-134a汽車空調系統使用 R-152a替代冷媒之研究 | zh_TW |
dc.title | Use R152a Refrigerant Alternative of R134a in the Mobile Air Conditioning Systems | en_US |